EMT
Source: GridKit/Model/EMT/README.md
Electromagnetic Transients (EMT)
This directory contains design documentation for electromagnetic transient (EMT) component models in instantaneous abc coordinates.
Conventions
These conventions reflect the current EMT model draft and may change as the EMT design and implementation develop.
Phase order is \(a\), \(b\), \(c\).
Equations use SI units unless a model states otherwise.
Current injection terms are written as positive into buses.
Model Categories
The current EMT documentation is organized into two categories:
BusComponent
Branch models such as BranchLumpedConstant are documented under
Component/Branch because they are EMT components connected to buses.
Open Design Notes
Distributed parameter lines are placeholders until internal signal delay support is designed.
Initial electrical wiring will use Delta configuration only