Texas
Source: examples/PhasorDynamics/Large/Texas/README.md
Synthetic Texas Case (ACTIVSg2000)
Case Description
This case is adapted from the ACTIVSg2000 synthetic Texas grid from the Texas A&M Electric Grid Test Case Repository: https://electricgrids.engr.tamu.edu/electric-grid-test-cases/
It is configured with GridKit-compatible dynamic models.
Model |
Count |
|---|---|
2000 |
|
3206 |
|
1507 |
|
544 |
|
544 |
|
544 |
Data Notes
Generator
6215_1in source data hadXl == Xdpp == Xqpp = 0.2011, which can trigger division-by-zero during GENROU initialization.In this case,
Xlwas reduced to0.1911to satisfyXl < Xdpp.
Events
The following event types are provided for this case.
Bus fault
Outstanding
Dynamics
Have not been implemented in GridKit:
ESAC1A
ESDC1A
ESST4B
EXAC2
EXPIC1
SCRX
GGOV1
HYGOV
IEEEG1
GENSAL (In GridKit, not added to this case yet)
IEEEST (In GridKit, not added to this case yet)
The following examples needs to be constructed with this case.
Line Outage
Generator Outage
Forced Oscillations
Statics
GridKit models Switched Shunts and Transformers with constant impedance, but this erases information and our ability to statically re-initialze the model if initalizing at a different operating point.
Switched Shunts
Transformers (LTC and Tap Ratios \(\neq 1\))