# Hawaii _Source: `examples/PhasorDynamics/Medium/Hawaii/README.md`_ ## **Synthetic Hawaii** ### One-Line Diagram ```{image} ../../../../../../examples/PhasorDynamics/Medium/Hawaii/hawaii.png :align: center ``` Figure 1: Oneline of the synthetic Hawaii case, courtesy of [PowerWorld](https://www.powerworld.com/WebHelp/) (WIP Updated Oneline) ### Case Description This case is a modified version of the synthetic Hawaii case, available at the Texas A&M University [Electric Grid Test Case Repository](https://electricgrids.engr.tamu.edu/electric-grid-test-cases/). It has been modified to include GridKit-compatible generator models. Model | Count ------------|-------- [Bus](../../../../../models/generated/phasor-dynamics/bus/index.md) | 37 [Branch](../../../../../models/generated/phasor-dynamics/branch/index.md) | 89 [GENROU](../../../../../models/generated/phasor-dynamics/synchronous-machine/genrouw-s/index.md) | 39 [TGOV1](../../../../../models/generated/phasor-dynamics/governor/tgov1/index.md) | 39 [IEEET1](../../../../../models/generated/phasor-dynamics/exciter/ieeet1/index.md) | 39 [IEEEST](../../../../../models/generated/phasor-dynamics/stabilizer/ieeest/index.md) | 14 [LoadZIP](../../../../../models/generated/phasor-dynamics/load-zip/index.md) | 28 [SignalNode](https://github.com/ORNL/GridKit/tree/lukel/readthedocs-dev/GridKit/Model/PhasorDynamics/SignalNode) | 131 ### Data Notes None. ### Events The following event types are provided for this case. - Bus fault ### Outstanding #### Dynamics The following models are not implemented in GridKit and are represented using surrogate models. - IEEEST (In GridKit, not yet added to this case) - REGCA - IEEEG1 - GGOV1 - ESST4B - REECA1 - EXST1_PTI - ESST1A The following examples needs to be constructed with this case. Currently the only events that have been implemented are faults. This is a practical case to use for modeling outages, or even forced oscillations. - Line Outage - Generator Outage - Forced Oscillations #### Statics GridKit models Switched Shunts as [Load](../../../../../models/generated/phasor-dynamics/load/index.md) with constant impedance,but this erases information and our ability to statically re-initialze the model if initalizing at a different operating point. - Transformers - Switched Shunts